12VDC 1.5Amp (18Watt) power adapter from 110 - 240VAC, plug 5.5 / 2.1mm
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
1 channel detection of fluid leakage with MODBUS
Shutter local alarm of detection of water leakage
Acoustic alarm - adjustable
RS485 2-wire MODBUS RTU
2 x LED indicators for power and alarm
Relay output for alarm for water leakage - 30VDC / 2A
Monitor cable for liquid detector
Sensor cable can be up to 500 meters
Sensitivity is adjustable
Supports DCON and Modbus RTU protocols
Embedded Dual Watchdog
Operating temperature: -25 to + 75 ° C
Small form factor with DIN bracket
Dimensions: 83 x 70 x 29 mm
Operating voltage: 10 - 30VDC
M485-LEAK1-I Liquid Leak Detection Module is a low cost, smart fluid leak-detection unit, with an alarm relay output. No extra conversion module is necessary, and M485-LEAK1-I can be easily integrated into a variety of monitoring systems to achieve remote alarm and remote control of the unit. M485-LEAK1-In Liquid Leak Detection module can be used to monitor the double cable cable lengths up to 500 meters and can be used with both the extended cable and the supplied detektionskabel for fluid leaks. If liquid is detected, activates the controller immediately output relay. The module can be easily integrated with other devices connected to the network. M485-LEAK1-I is suitable for detecting leakage in real time at critical points, such as Server rooms, warehouses, libraries, museums and industrial plants, and also for air handling equipment, refrigeration units, fluid reservoirs or pumping stations etc., Where there is a need to monitor any leakage the equipment.
If required, communication with M485-LEAK1-I programmed based on Modbus RTU protocol with the added benefit that different addresses can be configured via hardware to enable Modbus RTU communication.
Rev: LO
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
The motion sensor light detection, temperature sensor for energy management
Connects energy management, local-lighting control via RS485 port
With powerful built-in relay for simple light activation 250VAC (1500 Watt T8 )
360 ° motion detection - up to 8 m in diameter and 4 meters height
Time delay / Sensitivity is adjustable
temperature sensor, - measuring the room temperature or fire alarm
Relay output to turn on the light via the PIR / light-strength and temperature sensors
RS485 2-wire communication bus
DCON and Modbus RTU protocols
ceiling surface mounted design
Supply voltage: 10 - 30VDC ca. 2W
Dimensions: Ø121 x 52 mm | IP20
3 solid state relæudgange (kun til AC)
4 optoisolerede digitale indgange
Serial to HART Convert
Allows 2 pcs. Hart Masters
Point-to-Point or Multi-Drop Hart Mode
Possibility of connecting 15 HART modules
Point-to-point or multi-drop HART mode
for configuration of modules
Isolated COM 1: RS-232 / 422/485
PWR / RUN / ERR INDICATION LED
Built-in Watchdog
4 kV ESD protection
Expansion Modul til X-400-I og X-600M-I
8 x slutterelæ 125VAC / 30VDC 2,5Amp
10 polet interconnection fladkabel til Controller
RS485 kommunikation mellem enhederne
Forsyningsspænding: 9 - 28VDC fra Controller