Built-in module with screw terminals
5 x digital inputs, Wet Sink / source. 0 - + 50VDC
All inputs are with 32bit counter
2 x relay outputs 30VDC / 2A to 4 x 35 VDC relay outputs 6A, 6A
Relays 250VAC is non-inductive load
ARM Cortex - A53 CPU , 1.2 GHz
RAM 1Gb SDRAM
16GB of memory
2 x RS232/422/485
8 x DI and 4 x relay outputs
DC input 9-32V
4G module
OS : Linux Raspbian
User need knowledge of linux and programing
Documentation for DI/O and 4G module
Built-in Web server Logical functions with IF-THEN-ELSE setting IF-THEN-ELSE for simple set of conditions No more programming. Just click and finished Supports I / O, counter, timer, calendar, e-mail, rules Data Logger and data files supported rewind feature Modbus TCP / RTU protocol for SCADA software seamless integration I/O-Board XW with inputs and outputs Supports I-7000 Remote I / O modules (up to 16) Supports Modbus RTU slave units (up to 10) SNTP time synchronization supported Support SMS (GSM: Quad-band 850/900/1800/1900 MHz) Supply voltage: 12 - 48VDC
Measures: -20 ~ + 60 ° C and 0 ~ 100% RH
Accuracy: ± 0.4 ° C; ± 3.0% RH
LCD display shows the temperature, humidity, dewpoint and
module ID
10 ~ 30 VDC power input
IP66 Waterproof
Data Logger
Memory for temperature and 4,088 humidity records
RS-485 communication interface
DCON or Modbus RTU
Advanced Controller with logging
With slot for internal I/O expansion module, A/D, D/A, D/I, D/O, relay
Program with simple logic functions - WISE (Web Inside Smart Engine)
Logic functions with IF-THEN-ELSE logic
Supports SNMP, SMTP, FTP, MQTT, Modbus / TCP / RTU and DCON
Ethernet 10/100 / 1000Mbit
Setup via the built-in Web server
1 x RS232 port
2 x RS485 port
Supply voltage: 12 - 48VDC
The integration module with screw terminal
8 x digital inputs 0 - + 50VDC
All inputs with 32 bit counter (50 Hz)
8 x digital outputs, the Open Collector + 50VDC 700mA / channel
Multifunction concealed board
with 4 x AI, AO x 2, 4 x DI, 4 XDO
individual channel configuration
Jumper selectable voltage- or current input
Broken kabeldetektion by current measurement
Configurable settings for the initial value
digital input channels can be used as 32-bit counters
120 VDC surge protection to the analog input
60 VDC surge protection for digital input
Overload protection for digital output
Short circuit protection for digital output
Insert module for L-Con log series
4 x differential analog inputs 4 - 20mA
or 8 single-ended analog inputs 4 - 20mA
Resolution: 12bit
Sample Rate: 4khz
2 x Analog Output 4 - 20mA
Resolution: 12bit
3 x Digital Input (DRY) - Contact to GND
3 x Digital Outout (Open Collector) + 40VDC / 200mA per port
Dim: 82 x 66 x 13 mm
with screw terminal block
The logger / controller with socket for internal I/O expansion bus (eg. Relay module)
is programmed with simple logic functions
IF-THEN-ELSE, AND and OR simplifies the setup
supports SNMP, SMTP , FTP, Modbus RTU and DCON
Ethernet 10/100/1000Mbit
setup via the integrated Web server
2 x RS232 ports
2 x RS485 ports
The logger / controller with socket for internal I / O expansion bus (eg. Relay module)
is programmed with simple logic functions
IF-THEN-ELSE, AND and OR simplifies the setup
supports SNMP, SMTP , FTP, Modbus RTU and DCON
Ethernet 10/100 / 1000Mbit
setup via the integrated Web server
1 x RS232 ports
1 x RS485 ports
Supply voltage: 12 - 48VDC