![DIN bracket kit for Teracom...](https://debugger.danbit.dk/demo/16642-home_default/din-bracket-kit-for-teracom-units-2-brackets-in-plastic-screws.jpg)
DIN bracket kit for Teracom units. 2 brackets in plastic + screws
DIN kit for Teracom devices
2 x Bracket + 4 screws
Remote control over Ethernet may be the measurement and control with separate module located where the measurement is to be collected.
Ethernet remote monitoring provides a graphical user interface in the form of a web server and a M2M protocol, e.g. . MODBUS. They may be used in a stand-alone system or as part of a SCADA Systems. No need for special software to work with the devices. All settings and subsequent remote...
Remote control over Ethernet may be the measurement and control with separate module located where the measurement is to be collected.
Ethernet remote monitoring provides a graphical user interface in the form of a web server and a M2M protocol, e.g. . MODBUS. They may be used in a stand-alone system or as part of a SCADA Systems. No need for special software to work with the devices. All settings and subsequent remote monitoring and control is a standard browser - Chrome, Firefox, IE, Opera, etc.
TCW1xx units are simple tasks and do not have data logger function. TCW2xx units are with 32-bit chipset and supports 10 / 100MBit network. Everyone M2M protocols - Modbus TCP / IP, SNMP v2, HTTP API with XML / JSON status files and HTTP Post for client-server systems. They support TLS encryption for SMTP. Some data logger functionality and the user can view and retrieve log data via a standard browser.
There are 10 products.
Active filters
DIN kit for Teracom devices
2 x Bracket + 4 screws
Multi-Network Output Module with Galvanic I / O
10/100 Mbit Ethernet Connection
Password Protected WEB Server
2 Analog Outputs with Voltage and Power Generator
0 - 20mA, 4 - 20mA, 0 - 24mA
0 - 5V or 0 - 10V voltage output
4 digital (open drain) outputs with ON / OFF or PWM
2 relays with COM, NO and NC contacts
4 scheduled actions, 1 time or weekly
NTP, SNMP v2, SNMP trap for up to 5 recipients
MODBUS TCP / IP
HTTP upload with current status in XML or JSON remote server file
HTTP API commands in server and client mode
HTTP Post can be sent to 3 servers
DIN rail / wall mounting
Supply voltage: 10 - 32VDC / max 250mA
Module with smart temperature and moisture measurement and control
Password protected Web based configuration and control
1-Wire interface for 2 temperature sensors
2 x analog inputs from 0 to 60VDC - 10bit resolution, 100mV display
2 x digital inputs with "dry contact" and "logic level" mode
2 x relay output with NO / NC contacts
E-mail broadcast by alarm
SMTP with authentication (SSL / TLS is not supported)
SNMP v.1
SNMP traps generated alarm for HTTP and XML API commands
Remote firmware update.
Module with password protected Web based configuration and control
1-Wire interface for 2 sensors
2 x relay outputs with NO / NC contacts
2 x analog input with 0 to 60VDC
2x digital input with "dry contact" or "logic level" mode
Stable IP watchdog monitoring - for restarting equipment
SNMP v.1 support
SNMP trap conditional messages
VLAN and MAC address filtering
Remote FTP firmware update.
12VDC - purchase PSU
Open board til smart temperatur- eller fugt måling and styring
Password beskyttet Web baseret konfiguration og kontrol
1 x digital input med “dry contact” og “logic level” mode
1 x analog input fra 0 til 60VDC
1 relæ output med NO/NC kontakter
1-Wire input til 1 temperature eller fugtmåler
SNMP v.1 support
SNMP traps ved alarm
E-mail udsendelse ved alarm
SMTP med godkendelse (SSL/TLS er ikke supporteret)
HTTP og XML API kommandoer
Remote FTP firmware update.
Web based Data collector module with built-in WebServer
Supports MQTT 3.1.1 protocol
4 x digital input Dry - external contact without voltage
4 x analogue inputs with 0 to 10VDC, 0-20mA
4 x powerful relay outputs with NO/NC contacts
RS485 port
MODBUS RTU up to 24 registers (sensors)
Modbus TCP/IP support
Data logger with memory for 70,000 logs
SNMP v3 support with trap alarm
4 pcs. schemes for real-time control of relay
Up to 24 independent alarms
Secure email
XML/JSON and HTTP API commands for client-server
Dynamic DNS support for DynDNS, No-IP and DNS-O-Matic
NTP time sync
Supply voltage: 10 - 32VDC - purchase PSU
Dimensions: 145 x 90 x 40 mm
Multi input data logging for up to 70000 login
10/100 Mbit Ethernet
Password protected, web-based configuration and control
4 digital inputs, compatible with S0 pulse interface
6 analog inputs with 0 / 10V and 0 / 20ma
Modbus RTU interface for up to 24 sensors (registers)
Up to 24 channels for monitoring
Up to 24 Independent Alarms
SNMP V.2 Support - SNMP Trap - Alarm Alerts
HTTP and SNMP port change - HTTP API commands
Periodic HTTP post of XML / JSON Status files for client server systems
Modbus TCP / IP support
Dynamic DNS with dynns, no- IP and DNS-O-MATIC Support
NTP protocol support
supply voltage: 10 to 32V DC
Data logger for external temperature and humidity sensors
Sensors are not included - must be purchased separately, see selection
Memory for 70,000 measurements
Temperature, humidity and dew point can be displayed graphically
1-Wire and RS485 sensor interface
Up to 8 Teracom sensors can be connected
MODBUS TCP/IP support
SNMP v2 with trap alarm for 5 email recipients
Secure email
XML/JSON and HTTP API commands for client-server
Dynamic DNS, DynDNS, No-IP and DNS-O-Matic
NTP support for time synchronization
Remote firmware update
Supply voltage: 10 - 32VDC - purchase PSU
Stand-alone Data logger via Ethernet
Memory for 70,000 measurements
Can be programmed to log every 3 seconds
Password protected Web based configuration and control
2 x digital input "dry contact"
2 x analog inputs 0 to 10VDC, 10-bit resolution, 10mV display
Multiply and offset for analog input
2 x relay with NO/NC contacts
1-Wire interface for 8 sensors
SNMP v.2 support
SNMP traps up to 5 alarm types
MODBUS TCP/IP support
E-mail to 5 recipients in case of conditional alarm
HTTP API commands
NTP and dynamic DNS support
Remote firmware update
Supply voltage: 10 - 32VDC - purchase PSU
Web based data collector module with built-in Web server
4 x digital input dry - External contact without voltage
4 x analog inputs with 0 to 60vdc - 10mv resolution
multiplier and offset for analog inputs and sensors
1-wire for a maximum of 8 sensors (16 parameters)
4 x Powerful relay outputs with No / NC Contacts
Modbus TCP / IP Support
SNMP V2 Support with Trap Alarm for 5 Recipients
4 PCS. Forms for real-time control of relay
Specific logical functions for relays
Secured email
XML / JSON and HTTP API commands for Client server
Dynamic DNS support for Dyndns, No-IP and DNS- O-Matic
NTP TimeSync
Supply voltage: 10 - 32VDC - Buy PSU
Dim: 145 x 90 x 40 mm