![2 inputs for Strain Gauge,...](https://debugger.danbit.dk/demo/6538-home_default/2-inputs-for-strain-gauge-1-x-excitation-output-1-x-digital-in-4-x-digital-out-rs485-bus-display.jpg)
2 inputs for Strain Gauge, 1 x excitation output, 1 x digital in, 4 x digital out, RS485 bus, Display.
RS485 Module for load cells
2 analog inputs for 4 wire load cell,
1 excitation Exit
1 Digital input
4 digital outputs
Supply: 10 - 30VDC
There are 14 products.
Active filters
RS485 Module for load cells
2 analog inputs for 4 wire load cell,
1 excitation Exit
1 Digital input
4 digital outputs
Supply: 10 - 30VDC
1 A/D indgang til vejecelle,
1 D/A udgang
4 digitale udgange
RS485 module with volt / mA output. Digital input
4 x analog output - 0 - +/- 10V and 0-20mA
Resolution: 14bit
5 x Digital input - Active high on contact for frame
RS485 Bus - Module is Slave
Format: (N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1)
Baud Rate: 1200 ~ 115200 bps
Supply: 10 ~ 30 VDC
RS485 module with 2-channel strain gauge gauge
high resolution: 16-bit
excitation voltage range: 0 ~ +10 V.
50 Hz Event counter (digital input)
high / low alarm (Digital Output)
Linear Map Function
3000 VDC Intra Module Isolation
Double Watchdog
Temperature Area: -25 to + 75 ° C
Supply Voltage: 10 - 30vdc
Dim: 123 x 76 x 35 mm
Power or Voltage Output
0 - +10VDC, 0 - 20mA, 4 - 20mA
Resolution: 12-bit
Software Selectable Power or Voltage Output
Output Cable Detector for Power Output (4 - 20mA)
Backlink Voltage or Current
Configurable Power-on Value
Configurable Safe Value
3000 VDC Intra Module Isolation
Programmable Output Slope
Dual Watchdog
Temperature Range: -25 to +75°C
8 channel analog input module for RS485 Bus
16bit resolution
10 measurements per second (total)
for current measurement - shunt with 125 ohm resistance
Supply voltage: 10 - 30vdc / 1.3 watt
Dim: 123 x 72 x 35 mm
with your bracket
8-channel True RMS Input
±0.15% factory calibrated accuracy
The RMS input range can be from +150 mVrms to +10 Vrms
Designed for standard operation with frequencies of 45 Hz to 10 KHz
Channels can be individually configured
RS-485 Interface
DCON Modbus/RTU Protocol
8 x Analog Inputs
4 x Relay Outputs
DIN rail / wall mount
Temperature: -25 to +75°C
ANALOGT INPUT MODUL TIL MODBUS
RS485 module with 4 analog outputs
0-20mA or 0 - +/- 10V
D / A response time: 10ms
Resolution: 14bit
Supply voltage: 10 - 30vdc
Module for PT100 or PT1000 sensor with 4-, 3- or 2-wire
for nickel temperature sensor (Ni RTD)
16 bit resolution
15 Measurements per second (Total)
Supply voltage: 10 - 30vdc / 1 Watt
Master RS485 must establish bias voltage
Dim: 123 x 72 x 35 mm
RS485 Module for temperature sensors
1 x input for 2-, 3- or 4-wire PT100,Pt1000 sensor
Nickel Temperature sensor
Supply voltage: 10 - 30vdc
RS485 Module for measuring voltage and power
is with 15VDC transmitter output for power loop
1 x analog input 0-20MA, 0 - +/- 10V
1 x digital input. High is closed Contact
2 x Digital output (Open Collector) + 50VDC / 30mA
Supply voltage: 10 - 30VDC
Dim: 123 x 72 x 35 mm
20 channel analog input module for RS485 Bus
16bit resolution
20 Single Ended inputs (common frame) - Only for Volt
10 differential entrances for volts about power
10 measurements per second (Total )
Jumper Setting in the module
Supply voltage: 10 - 30vdc / 1.3 watts
Dim: 123 x 72 x 35 mm
DIN bracket