12VDC 1.5Amp (18Watt) power adapter from 110 - 240VAC, plug 5.5 / 2.1mm
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
The motion sensor light detection, temperature sensor for energy management
Connects energy management, local-lighting control via RS485 port
With powerful built-in relay for simple light activation 250VAC (1500 Watt T8 )
360 ° motion detection - up to 8 m in diameter and 4 meters height
Time delay / Sensitivity is adjustable
temperature sensor, - measuring the room temperature or fire alarm
Relay output to turn on the light via the PIR / light-strength and temperature sensors
RS485 2-wire communication bus
DCON and Modbus RTU protocols
ceiling surface mounted design
Supply voltage: 10 - 30VDC ca. 2W
Dimensions: Ø121 x 52 mm | IP20
M485-PIRTEMP-in module includes a 1-channel passive infrared (PIR) sensor, which is capable of detecting infrared waves generated by people within a range of about 8 meters in diameter with a 360 ° coverage area. M485-PIRTEMP-I used for indoor motion detection and can be configured to automatically turn on a light when motion is detected. M485-PIRTEMP-in module also contains a 1-channel temperature sensor that can be used for measuring the room temperature, or can be configured to activate a fire alarm. All communication with the M485-PIRTEMP-in module consists of commands generated by coughing and answers transmitted from the M485-PIRTEMP-In module. Each module is assigned a unique ID number which is used for addressing purposes and is stored in the module's flash memory. The module ID number is set by default to 01 and can be changed by sending a user command. All commands to the modules contains the ID number as the address, which means that only the addressed module will
answer. DCON commands is simple and starts with a "start" character followed by the "module address" (ID) (the module desired response from) followed by "Command" and a "checksum", ends with a CR (carriage return). The answer from the module containing data instead of Command. No module will on its own initiative send data on the RS485 bus. It is only cough which controls communication (polling principle). MODBUS communication is also a defined and widely used protocol.
Rev: LO
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
AC / DC power supply for DIN rail mounting
100-240V AC, 50 / 60Hz, 1.1A
Output, 24V, 1.7A (40 Watt)
Screw terminal
Adjustable output voltage
Short-circuit, overload and surge protection
Compact dimensions: 40 x 100 x 90 mm
Working temperature: -20-70 ° C
HMI Panel with LCD Display, Ethernet and Com Ports
Can be connected to most of the manufacturer's I / O modules
Power supplied from PoE or 12 - 48VDC / 2.5 Watt
RS-485 (with self-tunes) < Br> RS-232 (RX / TX / GND)
RTC - Real-time tour
GUI design
Free HmiWorks development tools
supports C and Ladder designer
design suggestions from manufacturer
Modbus TCP / RTU protocol
Dim: 140 x 87 x 41 mm
Network-based module with 16 digital inputs
built-in Web server
Web HMI
Support for both Modbus TCP and Modbus UDP protocols
Double watchdog
Wide operating temperature range: -25 ~ + 75 ° C
Built-in I / O
Digital input and counter: 16 channels
WEB-based data logger for temperature and humidity sensors
Can be programmed to 3 second sampling time
-55 - + 125°C, -40 - + 80°C 0 - 100%rH
4 pcs. 1-Wire bus for 16 sensors, each
Max. 64 pcs. temperature or temperature/humidity sensors
Max. distance to sensors: 180 meters
Tasks: 50 scheduled, 50 Conditional, 20 override
Email alerts, custom (encrypted email servers, such as gmail)
Real-time clock with NTP server synchronization
No software required
Configurable logging
Graph (logged data)
HTTPS/TLS encrypted
Static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP filtering
On-site is updated
For DIN rail / wall
Supply voltage: PoE or 9 - 28VDC, 134mA
Dimensions: 98 x 78 x 36 mm
Web-baseret I/O modul, Modbus/TCP / UDP
4 x Analog inputs (differential) voltage or current
Resolution: 16bit
Analog Input: +/- 10 V, 0 - 20mA (jumper)
4 x Analog outputs voltage or current
Analog output: +/- 10VDC, 0 - 20mA (jumper)
4 x Digital inputs (dry or wet), max. + 30VDC
I / O Pair-function - the input is mirrored to the second output
10 samples per second (fast: 50 samples)
Protocol: Modbus TCP / UDP
Supply voltage: 12-48 Volt DC / 5Watt