Measurement and control via USB port
16 x analog inputs 14bit, +/- 10V
Total Sample speed: 20KS / s
1 x Analog Exit 12bit, +/- 5V
8 X digital inputs TTL / CMOS
8 x digital outputs TTL / CMOS
1 x 16bit counter entrance
DAQ Software: Purchase NextView
Goal: 167 x 113 x 30 mm
Power supplied from the USB port
Measurement and control. Extremely powerful. Exactly measurement of input and get output signals with USB-AD16S14. High performance USB data arranged in aluminum house of high technical. Is particularly suitable for dynamic applications.
20 kHz Total sampling speed so that even the smallest peaks of high frequency signals are registered. The measurement range is selected via software for each channel separately.
Galvanic isolation of the analog channels, then the DAQ system and the PC are perfectly protected.
Digital modes are recorded or set to 4 digital inputs and outputs each. Digital inputs are sampled time synchronously with the analog inputs. The extra counter inlet is galvanically isolated.
Plug Play.
widely supported: The data collection system can be used under Windows® XP / 7/8/10 as as well as under Mac OS X, free BSD and Linux.
the complete Software for installation and programming is included for free.
DAQ software can be purchased - NEXTVIEW®. Try for free. The software for data collection and analysis. A fully functional 14-day sample is included in delivery to directly test the functionality of USB-AD14F.
WEB-based data logger for temperature and humidity sensors
Can be programmed to 3 second sampling time
-55 - + 125°C, -40 - + 80°C 0 - 100%rH
4 pcs. 1-Wire bus for 16 sensors, each
Max. 64 pcs. temperature or temperature/humidity sensors
Max. distance to sensors: 180 meters
Tasks: 50 scheduled, 50 Conditional, 20 override
Email alerts, custom (encrypted email servers, such as gmail)
Real-time clock with NTP server synchronization
No software required
Configurable logging
Graph (logged data)
HTTPS/TLS encrypted
Static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP filtering
On-site is updated
For DIN rail / wall
Supply voltage: PoE or 9 - 28VDC, 134mA
Dimensions: 98 x 78 x 36 mm
RS485 / RS422 / RS232 converter for Meter-Bus meters, actuators, etc.
Supports up to 100 Meter-Bus meters (slaves)
Selecting the serial port, only one can be selected to be active
2 x Baud rate (M-bus and COM port can be selected at different speeds)
Baud rate: 300 to 115,200 bps
Transparant data - no protocol conversion
M-bus connection is 2-wire , max. 350meter.
larger distance up to 5km requires a number of M-bus repeaters
Supply voltage: 10 - 30VDC, 1.8 - 12Watt
Dimensions: 122 x 72 x 33 mm | Removable terminal blocks
Operating temperature: -25 - + 75 ° C
DIN bracket
Robust plastic housing
Aluminum DIN rail bracket
Supplied without screws
The logger / controller with socket for internal I / O expansion bus (eg. Relay module)
is programmed with simple logic functions
IF-THEN-ELSE, AND and OR simplifies the setup
supports SNMP, SMTP , FTP, Modbus RTU and DCON
Ethernet 10/100 / 1000Mbit
setup via the integrated Web server
1 x RS232 ports
1 x RS485 ports
Supply voltage: 12 - 48VDC