RS485 / RS422 / RS232 converter for Meter-Bus meters, actuators, etc.
Supports up to 100 Meter-Bus meters (slaves)
Selecting the serial port, only one can be selected to be active
2 x Baud rate (M-bus and COM port can be selected at different speeds)
Baud rate: 300 to 115,200 bps
Transparant data - no protocol conversion
M-bus connection is 2-wire , max. 350meter.
larger distance up to 5km requires a number of M-bus repeaters
Supply voltage: 10 - 30VDC, 1.8 - 12Watt
Dimensions: 122 x 72 x 33 mm | Removable terminal blocks
Operating temperature: -25 - + 75 ° C
DIN bracket
Robust plastic housing
M-Bus ( "Meter-Bus") is a European standard for remote reading of gas meters, heat meters and other electricity meters. This bus meets the special requirements for remote or battery-powered systems, including consumption device sensors, various sensors and actuators. When incorporated into a network system, supplying the meters the measured data to a common MASTER, for example, can be a PLC, PC or handheld computer connected periodically to read all building meters. An alternative method to collect data centrally is to transmit meter readings via a modem.
M485-MBUS-I is specially designed to convert 2-wire M-Bus bus, connected to the meters to a serial port (COM -gate). There is a choice of RS-232, RS-422 or RS-
485th Only one of the three can be selected to be COM connection to the master (PC, PLC, etc.). On M485-MBUS-I are two rotary switches to serial port and M-Bus port baud rate.
When communicating using M485-MBUS In transparent data communications (no protocol conversion). Through these two options, it is easy to communicate with ethver standard M-Bus slave (measuring device with M-BUS).
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
RS485 module for 6 Temperature sensors
6-channel RTD input
3-wire RTD input with elimination of wire resistance
Resolution: 16-bit
Individual channel configuration
Disconnected sensor detection
Double Watchdog
Supply: 10 - 30vdc
Operating temperature: -25 to + 75 ° C
1 meter kabel til brug mellem I/O-kort og TERM100S
High resolution Color Touch screen
Poe (power over Ethernet)
RS232 Port, RS485 Bus
USB Download Port
RTC (Real Time Clock)
Gui Design
Free HmiWorks Development Tool
Supports C language and ladder designer
Modbus / TCP, Modbus / RTU and DCON protocol
Size: 126 x 92 x 29 mm
Operating temperature: -20 ~ 50 ° C
supports custom third-party protocol (C-language)
DIN rail
2 meters
Width: 3.5 cm
Height: 1.5 cm
TS35 Standard
Steel