2 x Analog to Load Cell, +/- 2.5V, 0-20mA, 1 x Excitation like cell, 2x digital zoom, 2 x Digital Output (OC). LAN
2 stk. analog indgange samt 1 analog og 2 digital indgange
Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
Good communication security
1 x RJ45 port Ethernet
Dual Watchdog
Operating temperature range: -25 to + 75 ° C
I / O Pair-connection input is mirrored in the other's output
8 x Analog differential input: output voltage and current
+/- 150mV - +/- 10V, 20mA +/- - 0 - 20mA
16-bit resolution, 10 samples per second
4 x Digital outputs - Open Collector, max. 50VDC / 700mA
Supply voltage: 10 - 30VDC / 2.8Watt
ETHIO8AI4O-I is a module with 8-channel differential analog inputs and 4-channel digital outputs. It provides programmable input range on all analog channels (+/- 150 mV, 500 mV +/-, +/- 1 V, +/- 5V, +/- 10V, +/- 20 mA, 0 ~ 20 mA and 4 ~ 20 mA) and the digital output can be set alarm output with short circuit protection and overload protection. Each analogue channel has allowed to set up an individual in the range of 240 Vrms and has high overvoltage protection. Each analog input can be programmed to accept the voltage or current as input depending on the position of the corresponding jumper. The sampling rate of ETHIO8AI4O-I can be changed; there are fast mode and normal mode for your consideration. ETHIO8AI4O-I also has qualification for 4 kV ESD protection as well as 2500 VDC isolation within the module.
2 stk. analog indgange samt 1 analog og 2 digital indgange
Measurement and control via USB port
16 x analog inputs 14bit, +/- 10V
Total Sample speed: 20KS / s
1 x Analog Exit 12bit, +/- 5V
8 X digital inputs TTL / CMOS
8 x digital outputs TTL / CMOS
1 x 16bit counter entrance
DAQ Software: Purchase NextView
Goal: 167 x 113 x 30 mm
Power supplied from the USB port
8 analog measuring inputs - up to +/- 10V, 0-20mA
Thermocoupler: J, K, T, E, R, S, B, N, C, L, M LDIN43710
USB interface
to measure the voltage, current, temperature.
up to 10 measurements per second.
Screw Terminal
RS-485 Interface
DCON Modbus/RTU Protocol
8 x Analog Inputs
4 x Relay Outputs
DIN rail / wall mount
Temperature: -25 to +75°C