12VDC 1.5Amp (18Watt) power adapter from 110 - 240VAC, plug 5.5 / 2.1mm
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
Remote collection of data, remote meter monitoring, energy management
Energy Meter Interface Module with MODBUS RTU
RS-485 interface with up to 63 units per BUS
Built-in 120 ohm termination resistor
Flash memory data and setup
Power supply from 5 to 32VDC, 25mA at 5VDC
Galvanic isolated digital input - 10mS pollinghastighed
Optional inputs: Open / Closed (dry contact and 32 bit counter)
S0 pulse counter applications :
Remote monitoring of electricity meters
Industrial process control
Remote monitoring of gas meters and water meters
monitoring devices with S0 outputs;
process monitoring
DIN rail mounting
Firmware update via interface.
Dim: 35 x 86 x 59 mm
TDI340 is an S0 pulse counter with MODBUS RTU interface. It has 4 isolated digital inputs that complies with S0 standard 62053-31. S0 pulse counter operates in polling or level-shift mode. In the level-shift lstand the module can be set to count on rising, falling and both level changes. The unit is a dedicated S0 pulse counter, but it also provides simultaneous readings of the state of digital inputs - OPEN / CLOSE.
Independent delay for transitions from low to high and high to low can is used. It may be delays from 0 to 656 seconds in 10mS steps and works if the counter for the corresponding digital input is in polling mode.
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
Multi input data logging for up to 70000 login
10/100 Mbit Ethernet
Password protected, web-based configuration and control
4 digital inputs, compatible with S0 pulse interface
6 analog inputs with 0 / 10V and 0 / 20ma
Modbus RTU interface for up to 24 sensors (registers)
Up to 24 channels for monitoring
Up to 24 Independent Alarms
SNMP V.2 Support - SNMP Trap - Alarm Alerts
HTTP and SNMP port change - HTTP API commands
Periodic HTTP post of XML / JSON Status files for client server systems
Modbus TCP / IP support
Dynamic DNS with dynns, no- IP and DNS-O-MATIC Support
NTP protocol support
supply voltage: 10 to 32V DC
DIN kit for Teracom devices
2 x Bracket + 4 screws
Temperature sensor TST300V2 with RS485 interface
±0.13°C accuracy from +20°C to +60°C
14 bit resolution
2 x RJ45 for daisy chain connection to the next sensor
IP20 sealed housing
Low power consumption
Modbus address table: see TST300 manual
Log in to danbit.dk and press DOWNLOADS
MODBUS RTU interface
Ivyko klaida
Multi sensor for CO2 and Barometric pressure
Interface: RS485 - MODBUS RTU
LED indicator for status of communication
Long-term stability based on digital signal processing
Self-calibration on fresh air for CO2 measurements
Changeable communication parameters
Non-volatile memory for all settings
Firmware update via the interface
Size: 81 x 81 x 30 mm
Weight: 66g
Supply voltage: 4,5 - 26VDC / Max. 150mA