12VDC 3 Amp (36Watt) from the AC adapter 110 - 240VAC, Jack: 5.5 / 2.1mm
Switch mode type
110-240 VAC for & nbsp; 12VDC / 3A
DC connector: 5.5 / 2.1 mm
GSM-alarm - ONLT FOR 2G
Setup via USB with Windows setup program, SMS and HTTP API
2 digital "dry contact" inputs
2 analog inputs, 0 - 10VDC - with resistance can be changed to input
2 mA analog inputs, 0 -10VDC or 0-20mA, 10bit (WEB control)
4 relay outputs, NO and NC
1-wire input for up to 8 Teracom sensors
RS485 interface for max. 8 MODBUS RTU sensors
data logger with memory for 70,000 logs
Upload data to HTTP Server
SMS alert to max. 5 recipients
Email alert for max. 5 receivers (SMTP with TLS support)
relay outputs with calls
12 to 24VDC, 350mA @ 12VDC - acquisitions PSU
TCG140 is a GSM-GPRS remote I / O module for distributed monitoring and control over the mobile network. The module can be used as an independent device or as part of data monitoring systems (SCADA).
The GSM / GPRS remote's I / O module has two digital "dry contact" inputs, two analog inputs with 0-10VDC and two analog inputs with 0-10V or 0-20mA. The analog input mode can be done via the GUI.
The device supports 1-Wire and RS485 (MODBUS RTU) interfaces. Both interfaces can have up to 8 sensors divided between the two interfaces in a random relationship.
The device records all monitored parameters in internal FLASH memory. The records are made at the previous set time interval and / or in an alarm mode. The log file can be periodically uploaded to a dedicated server using HTTP Mail.
The device has four relays with NO and NC contacts. The relays can be enabled externally (SMS, Cold or HTTP API command) or locally. For local activation, one of the monitored parameters is assigned to the relay - the alarm state of the parameter activates the relay.
The TCG140 can start a connection (HTTP Post) for remote dedicated servers. The payment load for this is an XML file, with current values for monitored parameters. The HTTP content can be sent periodically or under alarm conditions. In response to the HTTP content, an HTTP API command can be returned for relay activation or modification of some settings.
In addition to the HTTP Post alert, the device can send SMS and / or email as an additional warning to a maximum of 5 SMS and email recipients.
Switch mode type
110-240 VAC for & nbsp; 12VDC / 3A
DC connector: 5.5 / 2.1 mm
Temperature sensor with Dallas chip - up to 8 pieces on the same bus
1-wire communication to the measuring electronics
With connector for cascade coupling to the next sensor
±0.5°C accuracy from -40°C to +85°C
12 bit resolution
Temperature sensor in the box
Very low power consumption
Each device has a unique 64 bit serial number
1-wire lysmåler til synligt lys
0 - 83.000lux med 1 lux opløsning
Op til 23bit opløsning
Automatisk fuld skala justering
Kan kaskadekoples via RJ11 stik
Forsynes fra Controller med 5VDC/4mA
Maks. 30 meter kabel
Mål: 85 x 35 x 24 mm
IP30 plasthus med flange
Open board til smart temperatur- eller fugt måling and styring
Password beskyttet Web baseret konfiguration og kontrol
1 x digital input med “dry contact” og “logic level” mode
1 x analog input fra 0 til 60VDC
1 relæ output med NO/NC kontakter
1-Wire input til 1 temperature eller fugtmåler
SNMP v.1 support
SNMP traps ved alarm
E-mail udsendelse ved alarm
SMTP med godkendelse (SSL/TLS er ikke supporteret)
HTTP og XML API kommandoer
Remote FTP firmware update.
Web based data collector module with built-in Web server
4 x digital input dry - External contact without voltage
4 x analog inputs with 0 to 60vdc - 10mv resolution
multiplier and offset for analog inputs and sensors
1-wire for a maximum of 8 sensors (16 parameters)
4 x Powerful relay outputs with No / NC Contacts
Modbus TCP / IP Support
SNMP V2 Support with Trap Alarm for 5 Recipients
4 PCS. Forms for real-time control of relay
Specific logical functions for relays
Secured email
XML / JSON and HTTP API commands for Client server
Dynamic DNS support for Dyndns, No-IP and DNS- O-Matic
NTP TimeSync
Supply voltage: 10 - 32VDC - Buy PSU
Dim: 145 x 90 x 40 mm