1 PORT MODBUS serial port server, RS232 / RS422 / RS485 Modbus over Ethernet. Can run Modbus TCP Master
MODBUS
Serial Device Server
1 x RS232 / 422/485 port
Atop MB5001C
WIN XP / 7/8 / WIN 10
Web Server Config.
9 ~ 30 VDC
Intelligent Can For Modbus TCP / IP Converter
Supports both CAN specification 2.0A and 2.0B
Maximum transmission speed up to 1M BPS for CAN and 115.2 Kbps for RS-232 RS-485
Maximum transmission distance on CAN over 1000m (Follow the CAN specification)
7-segment LED display for module IP, RS-232 Baud rate, CAN configuration ...
Supports Web Configuration
Supports Maximum 24 Ethernet clients Connection
Modbus TCP / RTU command for reading and writing CAN message
Transparent communication between the CAN devices via Ethernet
30 Specific CAN IDs in Modbus TCP / RTU Mode
DIN mounting
M485-Eth-Can-MTCP is useful for data exchange between Modbus devices and CAN devices. M485-Eth-Can-MTCP is a Modbus TCP server and acts as a slave unit in Modbus RTU network. It supports four communication modes: Modbus TCP, Modbus RTU, Can-Ethernet Convert and Pair Connection.
The main function of the M485-Eth-Can-MTCP is Can for Modbus TCP / RTU gateway. It allows Modbus TCP / RTU to communicate with CAN device on a CAN network. M485-ETH-CAN-MTCP supports the function codes 0x03 / 0x04 / 0x10 for Modbus TCP / RTU for reading and writing CAN messages.
In addition, the device supports a transparent, protocol independent transfer of CAN messages, Which enables the implementation of it in a wide range of possible applications. Furthermore, the Can-Modbus converter can be used with various higher layers of can protocols (eg. Canopen, DeviceNet or other proprietary protocols).
MODBUS
Serial Device Server
1 x RS232 / 422/485 port
Atop MB5001C
WIN XP / 7/8 / WIN 10
Web Server Config.
9 ~ 30 VDC
Modbus over the Ethernet or Internet
MODBUS server with 1 x RS232 and 1 x 422/485
Can run Device to Device
0/100 Mbps Ethernet port, auto MDI / MDIX, 10/100 auto, 1500V magnetic insulation only on
RS485 RS232 Modbus ASCII / RTU port, 1 RS422 / 485 Modbus ASCII / RTU port, 16V / 400W TVS isolated, RS485 automatic line control
9 ~ 30VDC power input, IP30 enclosure , DIN rail mounting structure, USB port (Modbus serial port expansion and capture of memory)
Moxa MGATE 3180 1port RS232/422/485 Modbus TCP to serial.
Wifi CAN converter. CAN CAN bridge. CAN PC
two CAN channels
AP mode and station mode
Compatible with Socket (TCP Server, TCP Client, UDP)
Support: Ethernet, ARP, IP, ICMP, UDP, DHCP, DNS TCP)
DIP switch for terminating
Isolation: 1500VDC
CAN baud rate: 5kbit / s to 1Mbit / s
Wifi: 2.4GHz IEEE802.11a / b / g
Supply voltage: 9 - 30VDC
Consumption: 80mA @ 24VDC
Dimensions: 118 x 94 x 23 mm