![](https://debugger.danbit.dk/demo/17328-large_default/profinet-til-modbus-rtu-ascii-gateway--profinet-master-til-modbus-slave--kan-ogsaa-koere-modbus-master.jpg)
![Cable with 2 x DB100 Han, 5m](https://debugger.danbit.dk/demo/3070-home_default/2x-db100-han-kabel-5m-io-og-management.jpg)
Cable with 2 x DB100 Han, 5m
5,0 meter kabel til brug mellem I/O-kort og TERM100S
PROFINET / MODBUS konverter Gateway
PROFINET klasse B og RT klasse 1
1 x RJ45
Cyklisk tid: 1ms (min)
Generisk GSDML-fil (version 2.25)
Max længde af input/output data er 512/512 bytes
Understøtter Modbus Master og Slave mode
Understøtter Modbus RTU- og ASCII -format
RS232 or RS422 or RS485
Baud rate for COM1 fra 1,2 til 460,8 kbps
LED-indikatorer
4 kV kontakt ESD-beskyttelse til enhver terminal
Strømforsyning: +10 til +30 VDC
Driftstemperatur: -25 til +75°C
ETH-PROFI-MOD-I er specielt designet til PROFINET IO-enhed. Det giver PROFINET-controlleren adgang til Modbus-enheder. Disse Modbus-enheder kan være en PLC, eller en sensor, MODBUS 7000 serie moduler og så videre. Vi leverer også en hjælpesoftware til brugere til at konfigurere ETH-PROFI-MOD-I. Ved at bruge dette modul kan brugere nemt sætte deres Modbus-enheder ind i PROFINET-netværket.
5,0 meter kabel til brug mellem I/O-kort og TERM100S
Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
Good communication security
1 x RJ45 port Ethernet
Dual Watchdog
Operating temperature range: -25 to + 75 ° C
I / O Pair-connection input is mirrored in the other's output
8 x Analog differential input: output voltage and current
+/- 150mV - +/- 10V, 20mA +/- - 0 - 20mA
16-bit resolution, 10 samples per second
4 x Digital outputs - Open Collector, max. 50VDC / 700mA
Supply voltage: 10 - 30VDC / 2.8Watt
Expansion module for the X-400 / X-600 Controller series
8 x precise analogue inputs
Voltage Input: ±1.28V, ±2.56V, ±5.12V, ±10.24V
Current input, 4 - 20mA
Removable terminal plug
Driven via expansion bus - no power supply
High input impedance
Great for monitoring applications including:
Temperature
Electric current
Pressure
Fluid levels
With DIN bracket
Ethernet module with 2 digital inputs and 1 relay output
2 x digital dry contact - active high by connecting contact
1 x Power relay, 250vac / 5a, 30vdc / 5a
Avoid inductive load to relay
P2P Function that reflects an input to other module output
Supports Modbus / TCP and UDP Slave
Power supplied from PoE or 12 - 48VDC
PoE: IEEE802.3af, Class 1
Operating temperature: - 25 - + 75 ° C
Dim: 98 x 52 x 27 mm
DIN bracket