HMI 2.8" Controller Panel with Touch Display
Til mindre styringsopgaver, med TFT display og touch
Module to Can 2.0a and B
ISO 11898-2 standard
Baudrate 10Kbps for 1M bps
software for setting CAN and RS232 / 422/485
Transparency between RS-232 / 485/422 Via CAN bus
Full duplex on RS-232/422 units are not supported
CAN Bus Baud Rate Configuration
CAN Accept Filter Configuration
CAN 2.0A or 2.0B Specific Choice
RS-232 / 485/422 Baud rate and data file setting
RS-232/485/422 Respond Options
Setting: Normal or pair connection
PLC, HMI and SCADA are popular in the various industrial control applications, but most of them do not have CAN interfaces. Users always experienced difficulties due to connection of sensors or actuators that have only a CAN interface. The basic function of the M485-CAN-AI m is compatible with I-7530A, and "MR" stands for "Modbus RTU". So M485-CAN AI-M supports the Modbus RTU protocol in its RS-232/422/485 port. Modbus RTU is popular and widely supported by most PLCs, HMIs and SCADAs.
M485-Can-Ai-M is useful to use standard Modbus RTU protocol to access CAN network without problems . And with the specially designed firmware, in addition to normal received CAN message buffer, it offers special memory space to store up to 100 kinds of CAN messages that are urgent and must be treated immediately. The function helps PLC, HMI and SCADA use Modbus RTU function code 3,4,16 to access CAN devices in an easy way. In Modbus RTU mode, it allows a modbus RTU Master to communicate with CAN devices on a CAN network. The following figure shows the application architecture for this mode.
Til mindre styringsopgaver, med TFT display og touch
Wireless network-based digital I / O module with 1-wire port
1 x Power Relay 12amp, com No, NC
1 x Digital Input Optoisolated 0 - 26VDC
1-wire bus for 4 Temp / Moisture Sensors
Wi-Fi 802.11b/g/n
Antenna inclusive
Range up to 100 meters
Logging of input, counter value
Temperature, Moisture, relay mode and volt in
Basic script for advanced flexibility
Send email alarms (up to 8 email addresses)
Static or DHCP IP address
RTC with NTP server synchronization
No software required
XML, Modbus / TCP and Remote Services
On-site updates
Removable terminal connector
MODBUS TCP/IP module with analogue in- and output
User-definable Modbus TCP Slave addressing
Max. 10 clients connected
Supports RESTful API for IIoT applications
Supports peer-to-peer communications
Saves time and wiring costs with daisy-chain topologies
Active communication with WIN-OPC UA Server
Supports SNMP v1
Easy mass deployment and configuration with Device Search utility
Friendly configuration via Web browser
Temperature range -20 to +70°C
DIN Mount
Phoenix contacts
Supply 12 - 36VDC/ 3 Watt
Size: 124 x 84 x 28 mm
4 x Digital input and 4 x relay output
Form A and Form C Power relay
Source and Sink type of D/I
D/I the entries is also 16-bit counter
Configurable Power-on settings
Configurable Safe Value setting
Dual Watchdog
Temperature range -25 to + 75 ° C
Supply voltage: 10 - 30VDC
DIN bracket