12VDC 1.5Amp (18Watt) power adapter from 110 - 240VAC, plug 5.5 / 2.1mm
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
RS485 / RS422 / RS232 Master Gateway to Meter-Bus Slaves (sensors, actuators, etc.)
Supports up to 100 Meter-Bus meters (slaves)
MODBUS RTU function codes: 0x03 and 0x04 readdata
Selection of serial port, only one can be selected to be active
Baud rate x 2 (M-bus and COM port can be selected at different speeds)
Baud rate M-bUS: 300-2400 bps
Baud rate COM port: 300-115200 bps
Transparent data - no protocol conversion
M-BUS connection, 2-wire, max. 350meter.
Greater distance up to 5km requires a number M-bus repeaters
Supply voltage: 10 - 30VDC, 1.8 - 12Watt
Dimensions: 122 x 72 x 33 mm
Removable terminal blocks
Operating temperature: -25 - + 60°C
DIN mount
Robust plastic case
M-Bus ( "Meter-Bus") is a European standard for remote reading of gas meters, heat meters and other electricity meters. This bus meets the special requirements for remote or battery-powered systems, including consumption device sensors, various sensors and actuators. When incorporated into a network system, supplying the meters the measured data to a common MASTER, for example, can be a PLC, PC or handheld computer connected periodically to read all building meters. An alternative method to collect data centrally is to transmit meter readings via a modem.
M485-MBUS-MASTER-I is specially designed to convert 2-wire M-Bus bus, connected to the meters to a serial port (COM port). There is a choice of RS-232, RS-422 or RS-485th Only one of the three can be selected to be COM connection to the master (PC, PLC, etc.). On M485-MBUS-MASTER-I are two rotary switches to serial port and M-Bus port baud rate.
When communicating using M485-MBUS MASTER In transparent data communications (no protocol conversion). Through these two options, it is easy to communicate with ethver standard M-Bus slave (measuring device with M-BUS).
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
RS485 Module with 16 digital inputs
inputs are Dry Contact - High at contact to GND
RS485 The module is slave
supply: 10 - 30vdc
DIN bracket
The logger / controller with socket for internal I / O expansion bus (eg. Relay module)
is programmed with simple logic functions
IF-THEN-ELSE, AND and OR simplifies the setup
supports SNMP, SMTP , FTP, Modbus RTU and DCON
Ethernet 10/100 / 1000Mbit
setup via the integrated Web server
1 x RS232 ports
1 x RS485 ports
Supply voltage: 12 - 48VDC
Isoleret DC Voltage Input/Output Modul
3- vejs (power/input/output) isolation (1000 VDC)
Udvidet drifttemperatur (-25 ~ +75°C)
Til DINskinne montering
Input og output-stik på den modsatte side
Distributed I/O via Ethernet/RS485
Can be controlled via RS485 or Ethernet
10 x digital in 10 x relay out (mechanical relay)
9VDC ~ 24VDC supply voltage (power adapter included)
16bit / 100MHz CPU
256 KB ROM, 1 MB SDRAM