SUB-D DB37 male-female cable, gray, 1.8m
Forlængerkabel med DB37 han til DB37 hun stik
AWG28
Guldbelagte stik
16 analog inputs via USB port, 10-100S / S
Resolution: 12 bit
Sample-speed: 10Hz per channel
1 Analog output +/- 5V
4 digital outputs TTL ( CMOS
4 digital inputs TTL / CMOS
Power supplied from the USB port
DAQ Software: Purchase NextView
Measurement and control simple. USB-AD16S12+ is USB data collection system ideal for universal applications and because of the small size perfectly suitable for mobile use - just connect and get started! Extra small. Extra red. The unique idea of USB-AD16S12 + placed in D-sub housing is optimal for fieldwork.
Digital modes are recorded or controlled at 4 digital inputs and outputs each. Digital inputs are sampled time synchronously with analog inputs.
The device is supplied with power via USB interface. This reduces the cabling effort to a minimum and makes mobile measurements much easier.
The data collection system can be used under Windows® XP / 7/8/10 as well as under Mac OS X, free BSD and Linux.
Complete software for installation and programming USB-AD16S12+ is free. NEXTVIEW®. Try for free.
The DAQ system is supported by NEXTVIEW®, software for data collection and analysis.
A fully functional 14-day sample is included in the delivery to the test directly functionality of USB-AD16S12+.
Forlængerkabel med DB37 han til DB37 hun stik
AWG28
Guldbelagte stik
Terminal card with screw terminals
DB37 male / female cable of 1.8m included
For DIN rail mounting
103 x 85 x 50 mm (W x L)
4 x analog inputs with common GND
input voltage: ± 1.28V, ± 2.56V, ± 5,12V, ± 10,24V
Input current: 4-20mA - 200 Ohm Shunt resistance
2 X digital inputs / outputs: 0 - 5VDC
Digital I/O and Counter set up via the web server
1-wire bus for a maximum of 16 sensors
Temp/moisture/ultrasound, etc.
ermissions: Administrator, Manager , User
Tasks
50 Schedule Scheduled
50 Conditional
20 Torrect Scheduled
Email Alarms Based on Defined Terms
Supports Encrypted Email Servers, such as Gmail
RTC with NTP server synchronization
Basic script support for advanced flexibility
Logging and graph view
static or DHCP IP Address configuration
Modbus, SNMP, Remote Service, IP Filtering
37-polet terminalkort
16 stk. BNC 3
37 banan 4mm stik
RS485 I / O Module
7 digital inputs - Contact or volt in
8 digital outputs with connect contact function
Supply: 10 - 30VDC
Modbus Master Controller for max. 32 Modbus RTU devices
1-wire bus for a maximum of 16 sensors (temp / moisture etc.)
Tasks:
50 schedule planned, 50 conditional
20 Terrul Terms
Email Alarms by defined conditions
Supports encrypted email servers, such as Gmail
RTC with NTP server synchronization
No software required
Configurable logging
Graph (logged data)
HTTPS / TLS encrypted
static or DHCP IP address configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Robust cabinet for DIN rail / wall
Supply voltage: 9 - 28VDC