![](https://debugger.danbit.dk/demo/5980-large_default/ethernet-modul-med-2-digitale-indgange-1-relaeudgangpoe-digital.jpg)
![8 digital inputs to DC and...](https://debugger.danbit.dk/demo/6552-home_default/8-digitale-indgange-til-dc-og-ac-input.jpg)
8 digital inputs to DC and AC. RS485 bus. 10 - 30VDC
RS485 Module - Slave, with digital input
8 x digital inputs for DC and AC
Voltage monitoring
input voltage: 80 - 250VAC / DC
Supply: 10 -30vdc
Ethernet module with 2 digital inputs and 1 relay output
2 x digital dry contact - active high by connecting contact
1 x Power relay, 250vac / 5a, 30vdc / 5a
Avoid inductive load to relay
P2P Function that reflects an input to other module output
Supports Modbus / TCP and UDP Slave
Power supplied from PoE or 12 - 48VDC
PoE: IEEE802.3af, Class 1
Operating temperature: - 25 - + 75 ° C
Dim: 98 x 52 x 27 mm
DIN bracket
With different digital I / O functions, ETH-MODI1I-P-in an IP-based Ethernet I / O monitoring and control module. The module can be remotely controlled via a 10/100 M Ethernet network using Modbus TCP protocol. Modbus has become a de-facto standard communication protocol in the industry and is now the most common accessible means to connect industrial electronic devices. This makes ETH-mod2I1I PI perfect for integration with HMI, SCADA, PLC and other software systems.
Cost-effective Ethernet I / O modules (Modbus TCP / UDP-Slave) contains a 32-bit MCU that Effectively handles network traffic 10/100 Base-TX Ethernet, 1 x RJ-45 (automatic action, Auto MDI / MDIX, LED indicator). Includes redundant power inputs: POE (IEEE 802.3AF, Class 1) and DC input. Supports TCP, UDP, HTTP, DHCP, BOOTP and TFTP protocols. Support UDP responder for device discovery. Supports web configuration and firmware update via Ethernet.
Isolated Digital Input and Output supports locked di and 32-bit high speed counter features. Supports in / O pair connection via Ethernet.
Dual-Watchdog with power-on and secure value. Small shape factor with easy mounting on DIN rail.
Low power consumption (only approx. 1.7 W)
RS485 Module - Slave, with digital input
8 x digital inputs for DC and AC
Voltage monitoring
input voltage: 80 - 250VAC / DC
Supply: 10 -30vdc
RS485 Module for load cells
2 analog inputs for 4 wire load cell,
1 excitation Exit
1 Digital input
4 digital outputs
Supply: 10 - 30VDC
6 x digital inputs - Wet (active at DC input)
6 x Power relay outputs - 24VDC / 250VAC / 5A (COM, NO)
protocol: Modbus TCP / UDP
1 x RJ45 Ethernet Interface
I / O Pair Function - Input Mirrors for the second exit
digital inputs with counter - max 500Hz
Minimum pulse width: 1ms
Screw terminals: 10 - 30vdc / 3Watt
Compact Open Board with 8 relay exits
250V / 10A Only resistive load
Controlled from USB
supply voltage: 5VDC
supply via DC Jack or terminal block
No cabinet