Dataopsamler til trådløse dataloggere - kun til T&D blå serie
Dataopsamler med display og USB
Kun til T&D BLÅ SERIE Dataloggere
The 16-bit analog-to-digital converter
Versions: 0-20VDC, 0-10VDC, 0-5Vdc, 0-2VDC
With temperature compensation
4 Megabytes of memory to log data
USB and RS232, automatic baud rate up to 115.2kbit
Programmable input ranges (0-2 VDC, 0-20 VDC)
Battery operation - 10 year battery
Acc: Software for configuring, downloading, graphing, analysis and alarm reporting (supplied)
onfigurable controls alarm / surge control
Measurement speed of from 20 milliseconds (channel 1) to 12 hours
Robust aluminum housing
coated printed circuit board for protection against moisture, corrosion
Data loggers with 7 channels input, battery-operated, stand-alone high precision to 0-20VDC by up to 4MB flash memory.
Input current signals may be from sensors, transducers, transmitters or other conventional power sources. Its built
temperature channel provides environmental monitoring and temperature compensation.
Its aluminum body makes it ideal for the toughest industrial environments.
Plug Play USB port and versatile user-defined equations simplify the conversion of the unit.
16-bit ADC makes it suitable for science and laboratory purposes where accurate and precise measurements are critical.
Dataopsamler med display og USB
Kun til T&D BLÅ SERIE Dataloggere
Tænd/ sluk enhed via netværk 8 x 230V,forbrugs kwh med relæ styring af alle 8 udgange
1-wire lysmåler til synligt lys
0 - 83.000lux med 1 lux opløsning
Op til 23bit opløsning
Automatisk fuld skala justering
Kan kaskadekoples via RJ11 stik
Forsynes fra Controller med 5VDC/4mA
Maks. 30 meter kabel
Mål: 85 x 35 x 24 mm
IP30 plasthus med flange
CO2 - CO - temperature - humidity
Industrial / outdoor robust environment-measuring station
LCD color display
CO2 0-9999 ppm - electrochemical sensor
temperature of -20 - + 50 ° C, humidity 0 to 100% RH
dewpoint measurement based on the temperature and moisture
Up to 450,000 logs with date and time stamps
Web-based configuration interface
APP: iOS APP and Android APP, powerful software
DCON, Modbus RTU / TCP and MQTT protocols
RS-485 / Ethernet / PoE
Relay output for local alarm or building management
power supply: PoE and 12 - 48VDC ca. 3.5Watt
IP43 sealed enclosure (CO2 + temperature sensor)
Dimensions: 211 x 130 x 70 mm
DIN or wall mounting bracket