12VDC 1.5Amp (18Watt) power adapter from 110 - 240VAC, plug 5.5 / 2.1mm
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
Compact Modbus / TCP to RTU / ASCII gateway with PoE
not to be programmed
1 x RJ45 10 / 100Mbps
1 x RS232 (terminal block) - 5-pin
1 x RS485 (terminal block ) - 2-pin
baud rate up to 115,200 bps
Self-tuner for RS232
IEEE 802.3af - PoE (PD)
Supply voltage u / PoE: 12 - 48VDC 2Watt
Dimensions: 90 x 52 x 27 mm
DIN bracket
Operating temperature: -25 - +75°C
ETH-MODGW7xx series is a Modbus gateway that allows for a Modbus TCP / IP - UDP host to communicate with serial Modbus RTU / ASCII remote terminal units through an Ethernet network, thus eliminating the cable length limitation of legacy serial communication devices . The module can be used to create a pair-connection application (Pair-connection) as well as serial-bridge or serial-tunnel application) and can then route data over TCP / IP between two serial Modbus RTU / ASCII devices, is useful when connecting mainframe computers, servers or other serial devices using Modbus RTU / ASCII protocols and does not even have Ethernet capability. The maximum number of TCP connections for each serial port is up to 32 (RevB), this offers several Master access to slave devices on the same serial port. Read cache function is used to save previous requests and responses in the memory buffer in ETH-MODGW7xx. When other HMI / SCADA master controller sends the same requests to the same RTU slave device returns the cached answer immediately. This feature dramatically reduces the load on the serial
port communications and provides for faster TCP response, and improves the stability of the entire system.
Rev: LO
Mains adapter - switch mode type
110-240 VAC to 12VDC/1.5A
DC plug: 5.5/2.1 mm
1 meter cable
8 x analog inputs - Sample Rate 25 times per second
8 x input - Single ended: ± 1.28V, ± 2.56V, ± 5,12V, ± 10,24V
input 1 - 4 Can be 4-20mA
Web server for configuration and remote monitoring
Permissions: Administrator, Manager, User
Tasks
50 schedule planned
50 Conditional
20 overroubed
Email Alarms by Defined Terms
Supports Encrypted Email Servers, such as Gmail
RTC with NTP server synchronization
No software Required
Basic Script Support for Advanced Flexibility
Logging - Graph Presentation
static or DHCP IP Address Configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: 9 - 28VDC
Isoleret DC Current Input/Output Modul
3- vejs (power/input/output) isolation (1000 VDC)
Udvidet drifttemperatur (-25 ~ +75°C)
Til DINskinne montering
Input og output-stik på den modsatte side
Ethernet I/O module for the measurement of analog high-voltage differential inputs
8 x Analog input: +/-50V, +/-150V
4 x Digital output - Isolated Open Collector, max. 50VDC, 700mA per channel
16bit solution
Sample frequency: Normal mode 10 samples per second
Sample frequency fixed mode: 50 samples per second
Supports MODBUS TCP and UDP
Integrated Web Server - access with ID, password and IP filter
Power up and safe levels can be programmed
2 x RJ45 10 / 100Mbit ports - daisy-chain
Pair-connection - mirror one input to others output
Supply voltage: 12 - 48VDC 4,2Watt
Dimensions: 120 x 76 x 38 mm
Housing: plastic with DIN bracket
RS485 I / O Module
7 digital inputs - Contact or volt in
8 digital outputs with connect contact function
Supply: 10 - 30VDC